Sensors are robust and very easy to put into operation. Conventional alert systems require sensors to be installed in level with the ground, which takes at least 5 to 10 minutes but may take longer time in case of uneven terrain. In addition, the setting and initialization is done through a PC. Whereas, W-Seis is ready to use "as is", without requiring a PC, and the sensors, not needing any leveling, can be simply put on the ground.
| W-seis | |
| Sensor | Velocity seismograph(Geophone GS-11D) |
| CPU | Hitachi SH-2 processor |
| Detection method | Monitors P and S waves |
| Number of detection points and channels | 3points. 1up-down channel at each point. |
| Distance to detection point | 40 m for each point from the main unit. |
| Sampling frequency | 100Hz |
| A/D resolution | 24bits |
| Trigger level | 0.1 cm/s (low), 0.2 cm/s (medium) and 0.3 cm/s (high) for each point. |
| Detectable frequencies | 1.5 – 8 Hz |
| Set off condition | Warning is setoff when all 3 points peak the trigger level and the detection condition is met. |
| Power source | DC 12V; rechargeable battery (AC battery charger attached) |